芝柏吃鸡10个部位图片,机械师电影,他一边日一边吃我奶头-他一边日一边吃我奶头,《灭火宝贝2》美国版,少女潘金莲

PRODUCT

ENTERPRISE BRIEF INTRODUCTION

COMMODITY:Three Phase Anti-backcurrent Smart Power Meter

Model NO:DTSD9866-CD4-NL

Application Scenarios:Used in photovoltaic power generation system to actively prevent or control the situation of reverse current when the power generation power is greater than the actual load.

PRODUCT OVERVIEW

Using Din rail installation,especially suitable for applications with small Installation space,industry standard wide temperature

LCD  screen,with Good high and low temperature display characteristics,to achieve full power measurement and display,including

dynamic alarm,switching Input and output status,SOE event recording,complex rate,harmonics,etc,support RS485 communication,

can be configured to  Modbus -RTU Protocol.

Working Principle:

The Meter to be used with the inverter and the inverter adjusts the output power in real time through the power size and direction

of the network access port collected by the RS485 communication reading meter to achieve the anti-backflow function.

KEY FEATURE:   

  • Full power measurement & metering
  • DIN35 Rail Installation
  • High accuracy level
  • RS485 communication /ModBus RTU
  • Transformer input
  • Matching with inverter
  •  All or More Functions Customizable

 

Voltage

AC 57.7/100V、220/380V

 

Over load:1.2 times rated value(continuous):2 times rated value /1second:

 

Power consumption:<0.5VA(each channel)

 

Current

AC 1.5(6)A、100A/20mA、200A/100m etc

 

Over load:1.2 times rated Value(continuous):10 times rated Value/1second.

 

Power consumption: <0.5VA(each channel)

Accuracy

Voltage, Current, Power

Grade: 0.5

Active Power

Grade: 1 

Reactive Power

Grade: 2

Wiring Type

Three phase 3 line, Three phase 3 line

Frequency

45-65Hz

Power Supply

Working Range: AC/DC 85V~265V

Power Consumption: main body ≤5VA

Relay Output

Contact Mode: normally open(level output)

Contact Capacity: AC 250V/3A DC 30N/3A

Power Pulse Output

Output mode: optocoupler pulse with open collector

Switch Value Input

Support dry contact input, inner DC12V power supply

Communication

RS485 interface, support Modbus-RU protocol

Security

Power Frequency withstand Voltage

Among APS, voltage signal, current signal: AC 2kW/lmin:

Among switch value, pulse output, communication: AC 1KV/1min

Insulation

resistance

input, output to chassis>10MQ

Electromagnetic Compatibility Level

Comply with IEC 61000 standard(grade 3)

Protection Level

IP30

Working Environment

Temperature: -25℃~+70℃;

Display screen temperature: -20℃~+70℃;

Storage: -40℃~+85℃;

Relative Humidity: ≤95% no condensation;

Elevation: ≤2500.

INSTALL AND DIMENTION  

     Standard rail installation

TERMINAL DEFINING AND WIRING

 

 

DTSD9866-CD4-NL Three Phase Anti-backcurrent Smart Power Meter

贡-239| 魔兽人口普查| 甘心情愿原唱完趑版| 送别伴奏5sIng| 责溪油价| 性感视频网站| 民国侦探诡事录 电视剧| 花体字可复制| 棋牌室需要办理什么证| 河南通用定额发票真伪查询| 帕里斯·希尔顿| 黑色蕾丝女装大长腿| 詹姆斯比出la手势示爱主场球迷 | wlkblooddkpvp天慰| 衡山医院 电视剧| 蝴媒直播| 文化和旅游领域重大事故隐患重点检查事项 | 何以笙箫默电视剧免费观看全集 | 叶先国| 发生化险北学品事盐险族向什么方向险管 | 小红书曼干什么的| av在线| 安全你我他| 野左边助骨下经经作痛| 为什么老饰线| 《请好好疼爱里面》免费观看| 儿童挖据机视频大全视频播放| 创维电视质量好吗| 7777777亚洲和欧洲尺码表| 2b14881-2013食品安全国家标准 | 亚洲女子a中天字幕| 为女人花钱短刷全集免费| 萨利机长晾型| 《訾花交换做爰》| 色一情一乱一伦一视频免费看| 十年三月三十日| 八足马